VO1060 hardware evidence

Device and Protocol

Target USB identity: 2feb:000b. Local Linux sysfs exposes three hidraw interfaces. Interface 2 has numbered report 9, a 12-byte input payload (13 bytes including ID), and an 8-byte output payload (9 bytes including ID), verified from the attached device's HID descriptor.

The upstream VO1060 configuration provides initialization payloads 09 01 04 and 09 02 02, plus coordinate limits 50800×31750 and pressure maximum 8191. TabletKey pads output reports to the descriptor's nine-byte length. The upstream pen parser provides field layout evidence. The driver implementation was written independently; these references establish protocol facts, not runtime dependencies.

The official product image shows four mechanical keys, a center button in the dial, and the rotating wheel.

Captured Controls

The user recorded otd-unmapped-retry.jsonl after removing OTD's auxiliary mappings:

  • 38 thirteen-byte reports, all from interface 2, with a complete session end marker.
  • Five button press/release pairs, identifiers 08, 04, 02, 01, 10 in press order.
  • Button prefix 09 42 01; byte 3 alternates 01/00 for press/release.
  • Wheel prefix 09 42 03; byte 4 contains 02 or 01, with active/release pulse pairs.
  • Associating 10 with the center button remains an inference from the user's sequence.
  • Physical wheel polarity has not been isolated; UI mappings can be swapped.

The user later confirmed that physical keys 1–4 match identifiers 01, 02, 04, 08, in the order shown in the product image. The earlier mixed capture order did not establish physical positions. The UI default now follows this confirmed order; saved custom calibrations and hardware bindings are preserved.

Raw captures remain local under ignored captures/ and are not committed.

Standalone Verification — 2026-10-30

The first standalone attempt found permission denied on the target native input nodes. OTD was restored after cleanup. The user then ran TabletKey's explicit udev setup command. The subsequent test established:

  • OTD was stopped; executable inspection confirmed it was not running.
  • TabletKey's initialization writes succeeded on interface 2.
  • All three hidraw interfaces opened, and three native VO1060 evdev nodes were grabbed.
  • Virtual keyboard, mouse, and pressure-sensitive pen devices were created.
  • COSMIC routing selected the enabled primary output HDMI-A-1 at logical 1920×1080, offset 1920,0.
  • The user's existing native-device and OTD COSMIC routing entries were preserved.

TabletKey was then started as the real detached daemon with OTD stopped. The user was asked to unplug/replug the tablet and test pen and wheel; the user reported pen and scrolling work. Afterward, daemon status showed initialized/connected/pen-active, 2729 decoded pen reports out of 2794 total reports, and no device or output error. OTD remained stopped. This establishes operation after a fresh connection without a running OTD daemon.

Pressure Response Verification — 2026-10-31

The original response was linear against the declared 8191-count sensor maximum, with no user pressure adjustment. The new Pressure tab exposes sensor/mapped time history, a response preview, explicit sensitivity controls, and comfortable-peak calibration. Raw sensor values are preserved.

After restarting TabletKey with telemetry, the user selected Light touch and saved it, then reported that pressure feels right. Read-back confirmed full_input=0.65, gamma=0.7, and deadzone=0. The active driver observed a raw maximum of 6276, no reports outside the declared sensor range, and no device/output errors. This supports the response adjustment without evidence of an overflow or mismatched sensor maximum in that test. It is not a measurement of physical force linearity.

The 74-test suite includes identity response, monotonic curves, full-output scaling, deadzone/contact consistency, peak retention, idle reset, payload bounds, range diagnostics, profile migration, and GUI save.

Hover Capture — 2026-10-31

The user completed hover-range-test.jsonl while raising/lowering the pen with the mouse still. The complete capture contains 5409 thirteen-byte reports on interface 2: 5357 09 41 A0 hover reports, 50 09 41 A1 contact reports, and two 09 41 C0 reports. C0 follows in-range reports and precedes renewed hover, with exit-to-return intervals of 5.212 ms and 343.845 ms. This agrees with the upstream VEIKK V1 range-exit parser.

The old decoder ignored C0 and used a 500 ms silence fallback. Neither observed gap between valid pen reports exceeded that timeout (largest: 349.019 ms), so this capture does not establish that the timeout caused the reported cursor flicker. Explicit exits now release contact/proximity, and the new diagnostics distinguish hardware exits from silence timeouts. The user subsequently confirmed detection works, but could not reliably correlate cursor flicker with the counters and did not reproduce a problem during that check. No hover smoothing was added.

There is no established distance or signal-intensity field. Upstream's tilt decoder uses bytes 11–12 for signed tilt, not height. Millimetres require an external measurement; packet rate/gaps cannot be relabelled as detection intensity. Diagnostics retain binary transitions and timing only; no new raw capture logging is enabled.

Remaining Validation

Pressure decoding/output is implemented, but brush-width response in a pressure-aware drawing app has not been specifically confirmed. Multi-monitor crossing, crop/rotation ergonomics, sustained stationary contact, simultaneous controls, repeat behavior, and reboot/startup need further tests. Tilt and per-app profiles are not implemented. OTD was subsequently removed by the user; standalone operation remains the supported path.

Raw diagnostics remain read-only. Standalone daemon startup is the explicit device-initializing, native-input-grabbing path; do not confuse the guarantees of those two modes.